AKKUTEC 2440

DC-UPS for batteries, primary : 3x400 V, secondary : 24 V, output: 44 A, dimensions: 180x290x150 mm, weight: 3.6 kg

More details...

Availability : 1-2 weeks

AKKUTEC 2440

992,66 €

DC-UPS for batteries, primary : 3x400 V, secondary : 24 V, output: 44 A, dimensions: 180x290x150 mm, weight: 3.6 kg

 

Short Description

The battery backed up DC power supply in the AKKUTEC range uses the standby-parallel principle of operation and, in conjunction with a lead accumulator, ensures that the DC power supply is reliably maintained in the case of a mains power failure.

 

  •  The power supply has the following features:

  • Switched primary, switched power supply with I/V charging characteristic

  • Microcontroller-based battery management

  • Temperature compensation for charging voltage by means of external sensor module (optional module)

  • Display and control panel for switch cupboard door installation or surface mounting (option)

  • TEC-Bus on RS 232-Interface (optional module)

Technical Data

Rated input voltage

400 – 500 V AC

Input voltage range

360V - 550V     «       400V-10% - 500V+10%

Input frequency

45 – 65 Hz

Rated input current

2,75 A ( 400V AC )

2,2 A   ( 500 V AC )

Max. inrush current

65A / 5ms, i²t = 14A²s

System voltage

24 V DC

Output voltage

(depending on state of charge of the battery)

Voltage range

- without temperature sensor

- with temperature sensor

 

 

 

a) 19,8 V  DC...26,8 V DC

b) 19,8 V DC …28,0 V DC

Final charging voltage

- without temperature sensor

- with temperature sensor

 

26,8 V DC ±0,4%

27,1 V DC ±0,4% (at 25°C)

Charging characteristics

I/U DIN 41773-1

Deep discharge protection and load rejection at

19,8V DC ±0,4%

Nominal output current

40A DC

Constant current limitation

1,05...1,1xIANenn

Battery type

Pb-Akku, wartungsfrei
Pb-Akku, wartungsarm

efficiency

(Ua=26,8V DC, Ia= Nom

and Ue=400V AC)

91,5% (typ.)

max. power loss ‘worst-case’

115W

Earth leackage current

<3,5mA

Fusing primary

3 x 4AT (external)

fusing DC- output circuit

40 A slow acting (external)

Fusing battery load circuit

40 A slow acting (external)

Type of connection primary ‘mains’

Combicon-screw type terminal 2,5mm2

Fastening torque 0,5-0,6 Nm

Type of connection secondary ‘Ua’, ‘UBatt’

Screw type terminal 10mm2

Fastening torque 1,2-1,5 Nm

Type of connection interface
‘IO-1...IO-3’

Combicon-screw type terminal 1,5mm2

Fastening torque 0,22-0,25 Nm

Type of connection Current-Share-Bus ‘CS’

Combicon-screw type terminal 2,5mm2

Fastening torque 0,5-0,6 Nm

Display

 

Netzbetrieb

operation

LED green illuminates:

·  Mains operation
(UE>UEmin and TInt<TIntmax)

 

LED green
(battery voltage within the monitoring window 21,6< UBatt < 27,9V DC)

 

LED green
(battery voltage above the monitoring window UBatt  =27V DC

Fehler

LED red
LED illuminates at:

* Battery operation (during mains operation LED is not illuminated)

* Battery circuit interrupted respective high-ohmic (Testintervall 60s)

* Battery low

* Battery reverse poled

* Battery-over-temperature (only in connection with temperature tracking

Signal in- and outputs

 

Mains operation 1)

potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A

Fehler 1)

potentialfree relay-contact, changer, max. contact load 30 V DC/ 0,5A

 1)

potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A

 1)

potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A

Shut-Down

Shut down of UPS mode

Switch input, referring ot earth, switch level: 24V DC (16-80 V DC)

Starkladung (Boost charging)

Activation of boost charging (boost charging voltage 28.6 V DC)
Switched input referenced to earth, switching level: 24V DC (16-80V DC)

General

 

weight

appr. 3,3 kg

storage

recommended 0...30°C,
permissible 0...50°C

Operational temperature

recommended 10...20°C (battery life duration!),

permissible 0...40°C

Protective system

IP20

dimensions

290 x 180 x 147 mm (L x W x D)
see section 10

fixation

Top hat rail according to DIN EN 50022-35
Alternativ: assembly kit for direct screw fastening on the cabinet installation plate (option)

UL approvals

UL 508

C22.2

  • primary voltage 3x400 V
  • secondary voltage 24 V

30 other products in the same category :

AKKUTEC 2410

AKKUTEC 2410

607,55 €

AKKUTEC 2420

AKKUTEC 2420

824,82 €

AKKUTEC 2420

AKKUTEC 2420

824,82 €

AKKUTEC 2420-12

AKKUTEC 2420-12

1 132,55 €

AKKUTEC 19-2403-07

AKKUTEC 19-2403-07

846,14 €

AKKUTEC 19-2403-12

AKKUTEC 19-2403-12

893,96 €

AKKUTEC 19-2403 K

AKKUTEC 19-2403 K

327,60 €

AKKUTEC 2403 VdS

AKKUTEC 2403 VdS

401,75 €

AKKUTEC 2405-0

AKKUTEC 2405-0

403,36 €

AKKUTEC 2405-07

AKKUTEC 2405-07

624,03 €

AKKUTEC 2420-12

AKKUTEC 2420-12

1 132,55 €

AKKUTEC 2420-12

AKKUTEC 2420-12

1 132,55 €

AKKUTEC 2405-12

AKKUTEC 2405-12

681,53 €

AKKUTEC 2410-07

AKKUTEC 2410-07

842,91 €

AKKUTEC 2410-12

AKKUTEC 2410-12

900,42 €

AKKUTEC 2412 VdS

AKKUTEC 2412 VdS

755,68 €

AKKUTEC 2420-07

AKKUTEC 2420-07

1 076,66 €

AKKUTEC 2420-12

AKKUTEC 2420-12

1 132,55 €

AKKUTEC 19-2420-0

AKKUTEC 19-2420-0

1 364,68 €

AKKUTEC 19-2420-07

AKKUTEC 19-2420-07

1 654,32 €

AKKUTEC 19-2420-12

AKKUTEC 19-2420-12

1 710,37 €

AKKUTEC 2420-07

AKKUTEC 2420-07

1 076,66 €

AKKUTEC 19-2403-07

AKKUTEC 19-2403-07

846,14 €

AKKUTEC 19-2403-12

AKKUTEC 19-2403-12

893,96 €

AKKUTEC 2405-07

AKKUTEC 2405-07

624,03 €

AKKUTEC 2405-12

AKKUTEC 2405-12

681,53 €

AKKUTEC 2410-07

AKKUTEC 2410-07

842,91 €

AKKUTEC 2410-12

AKKUTEC 2410-12

900,42 €

AKKUTEC 2420-07

AKKUTEC 2420-07

1 076,66 €

AKKUTEC 19-2420-07

AKKUTEC 19-2420-07

1 654,32 €